Software, included with every. Telecom equipment Pulsar Evolution 2200 & 3000with 1 to 3 EXB battery extension. MGE’s innovative Pulsar Evolution meets the.
Full text of ' www.maeups.com Pulsar Evolution 2200/3000/3000 XL Installation and user manual E R M G E UPS SYSTEMS MGE UPS Systems 1660 Scenic Avenue Costa Mesa, CA 92626 (714) 557-1636 For service call 1 -800-438-7373 www.mgeups.com IMPORTANT SAFETY INSTRUCTIONS Read before installing product SAVE THESE INSTRUCTIONS. This manual contains important instructions for 89347, 89348, and 89349 that should be followed during installation and maintenance of the UPS and batteries. Thank you for selecting an MGE UPS SYSTEMS product to protect your electrical equipment.
The Pulsar Evolution range has been designed with the utmost care. We recommend that you take the time to read this man- ual to take full advantage of the many features of your UPS. MGE UPS SYSTEMS pays great attention to the environmental impact of its products. Measures that have made Pulsar Evolution a reference in environmental protection include: » The eco-design approach used in product development, ► recycling of Pulsar Evolution at the end of its service life.
To discover the entire range of MGE UPS SYSTEMS products and the options available for the Pulsar Evolution range, we invite you to visit our web site at www.mgeups.com or contact your MGE UPS SYSTEMS representative. This manual contains important instructions for Pulsar Evolution Models that must be followed during installation, operation and maintenance of the UPS and batteries. The Pulsar Evolution UPS Models that are covered in this manual are listed below.
Pulsar Evolution 2200, 3000, 3000XL The normal battery voltage for all models is as follows: Pulsar Evolution 2200-72V, 3000-72V The Pulsar Evolution UPS is intended for installation in a temperature within 0 to 40 Q C, free of conductive contaminant's. Note Tnis equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Page 2 - 34007231 oo/ad Introduction CAUTION: Safety of persons >The UPS has its own internal power source (the battery). Consequently, the power outlets may be energized even if the UPS is disconnected from the AC-power source.
>Dangerous voltage levels are present within the UPS. It should be opened exclusively by qualified service personnel. ► The UPS must be properly earthed. Measurements are required to ensure that the total leakage current of the UPS and the protected equipment does not exceed 3.5 mA by checking their characteristics (maximum leakage current of the UPS = 2 mA). » The battery supplied with the UPS contains small amounts of toxic materials.
To avoid accidents, the directives listed below must be observed: Never burn the battery (risk of explosion). Do not attempt to open the battery (the electrolyte is dangerous for the eyes and skin). Comply with all applicable regulations for the disposal of the battery. Batteries constitute a danger (electrical shock, burns).
The short-circuit current may be very high. Precautions must be taken for all handling: remove watches, rings, bracelets and any other metal objects, use tools with insulated handles. Do not lay tools or metal parts on top of batteries. CAUTION: Product safety t The UPS connection instructions and operation described in the manual must be followed in the indicated order. Sonik Synth 2 Vst Free Download. I UPS must be connected to a nearby wall outlet that is easily accessible. The UPS can be disconnected from the AC-power source by removing the power cord.
» Check that the indications on the rating plate correspond to your AC-power system and to the actual electrical consumption of all the equipment to be connected to the UPS. I Never install the UPS near liquids or in an excessively damp environment.
I Never let a foreign body penetrate inside the UPS. I Never block the ventilation grates of the UPS. ► Never expose the UPS to direct sunlight or source of heat. I If the UPS must be stored prior to installation, storage must be in a dry place. » The admissible storage temperature range is -25 2 C to +55 Q C. Special precautions I All handling operations will require at least two people (unpacking, installation in rack system).
I Once installed and connected to the AC power source for the first time, the battery will start to charge. Full charging to obtain the rated battery backup time requires at least 8 hours. I Before and after the installation, if the UPS remains de-energized for a long period, the UPS must be energized for a period of 24 hours, at least once every 6 months (for a normal storage temperature less than 25 °C). This charges the battery, thus avoiding possible irreversible damage.
During the replacement of the battery module, it is imperative to use the same type and number of element previously mounted in the UPS, in order to maintain an identical level of performance and safety. In case of doubt, don't hesitate to contact our after sales department (for more information, refer to the web site www.mgeups.com). 34007231 oo/ad - Page 3 Foreword Using this document Information may be found in two ways, using: i the contents; i the index. Pictograms O o A IMPORTANT: Important instructions that must always be followed. NOTE: Information, advice, help. WARNING: Indicates present eminent danger, precautionary action required. CAUTION: Indicates to proceed with caution, precautionary action required.
Visual indication. Audio indication. In the illustrations on the following pages, the symbols below are used: O LED off. LED flashing.
Page 4 - 34007231 oo/ad Contents 1. Presentation 1.1 Overall view 7 Tower position 7 Rack position 7 1.2 Back 8 1.3 Control panel 9 2. Installation 2.1 Unpacking and parts check 10 2.2 Upright installation (tower position) 11 2.3 Flat installation (rack position) 12 2.4 Connecting the protected equipment 13 2.5 Connection to the RS232 or USB communications port (optional) 14 2.6 Connection to the data-line protection port (optional) 14 2.7 Installation of the communications-card option 15 3. Operation 3.1 Start-up 16 3.2 Shift to booster or fader mode (during voltage variations in the AC-input power) 16 3.3 Operation on battery power (following failure of AC-input power) 17 Transfer to battery power 17 Threshold for the low-battery warning 17 3.4 Personalization (optional) 18 Function 18 ON /OFF conditions tab 18 Battery tab 18 Voltage-thresholds tab 19 Sensitivity tab 19 4. Maintenance 4.1 Trouble-shooting 20 4.2 Replacement of the battery module 21 5. Environment 1 oo/ad - Page 5 Contents 6. Appendices 6.1 Technical data 24 Simplified diagram 24 Technical characteristics 25 Examples of battery backup times 26 6.2 Glossary 27 6.3 Index 28 Page 6 - 34007231 oo/ad 1.
Presentation 1.1 Overall view Tower position Rack position Dimensions in inches (W x H x D) Evolution 2200 1724 (13)x3.56(2U)x 25.2 Evolution 3000 Evolution 3000 XL Weight in lbs Evolution 2200 75 Evolution 3000 82 Evolution 3000 XL 1 oo/ad - Page 7 1. Presentation 1.2 Back Pulsar Evolution 2200 0 USB communications port. (2) RS232 communications port.
(3) Connector for automatic detection of an additional battery module. (4) Data-line protection. (5) Slot for communications-card option. (6) Connector for an additional battery module.
(7) Output circuit breakers. (8) Six receptacles for direct connection of protected equipment. (9) Two programmable receptacles (1 and 2). (To) Input power cords for connection to AC-power source; 2200/5-20P and 3000/L5-30. (TT) Battery module connectors (to the UPS or to other battery modules). (fg) Connectors for automatic detection of additional battery modules.
(Q) Circuit breaker for battery ON/OFF and protection. Page 8 - 34007231 oo/ad 1.3 Control panel 1.
Presentation Illuminated ON/OFF button for the receptacles. Operation on battery power, -i- UPS fault. Battery fault.
Group 1 programmable receptacles supplied with power. Group 2 programmable receptacles supplied with power. Booster or fader mode. Bar graph indicating percent load at output. Bar graph indicating the battery charge level.
34007231 oo/ad - Page 9 2. Installation 2.1 Unpacking and parts check (26) RS232 communications cable for Windows Operating Systems. For UNIX/Linux Operating Systems, please order, for free, the following part number: 66090 (g) USB communications cable. (£§) Telescopic rails for mounting in 19' bay with mounting hardware.
Two securing systems for equipment power cords. (S3) CD-ROM with the Solution-Pac and UPS Driver software. (Sj) Product documentation. (52) Two supports for the upright position. Page 10 - 34007231 oo/ad 2.2 Upright installation (tower position) Connect the two supports for the upright position. Installation 34007231 oo/ad - Page 1 1 2.
Installation 2.3 Flat installation (rack position) Follow steps 1 to 6 for rack mounting of the UPS on the rails. The rails and the necessary mounting hardware are supplied by MGE UPS SYSTEMS. Page 12 - 34007231 oo/ad 2. Installation 2.4 Connecting the protected equipment CAUTION: Check that the indications on the rating plate on the back of the UPS correspond to your AC-power system and to the actual electrical consumption of all the equipment to be connected to the UPS. 1 - Remove the power cord supplying the equipment to be protected. - Pulsar Evolution 2200/3000/3000 XL: Connect the supplied input power cord @) to the AC power wall receptacle.
2 - Connect the protected equipment to the UPS using the rotation power cord @. It is advised to connect priority loads to the four standard receptacles (?) and any non- priority loads to the two programmable receptacles (5). Olf the UPS is connected to a com- puter running MGE communica- tions software, it is possible to pro- gram the interruption of power to the programmable receptacles (9) during operation on battery power, thus reserving backup power for the priority loads.
3 - Lock the connections using the securing system (23). As soon as the UPS is energized, the battery begins charging. Eight hours are required to charge to the full rated back- up time. NOTE: Pulsar Evolution 3000 XL: At least one EXB additional battery module must be connected to the UPS because it does not have internal batteries.
See the EXB battery-module installation manual (Doc. ) for information on making the connections. 34007231 oo/ad - Page 13 2. Installation 2.5 Connection to the RS232 or USB communications port (optional) A A CAUTION: The RS232 and USB communications ports cannot operate simultaneously. 1 - Connect the RS232 @ or USB @ communications cable to the serial port or the USB port on the computer. 2 - Connect the other end of the communi- cations cable @ or @ to the RS232 @ or USB (T) communications port on the UPS. The UPS can now communicate with all MGE UPS SYSTEMS supervision, set-up or safety software.
2.6 Connection to the data-line protection port (optional) The data-line protection function on the UPS eliminates overvoltage flowing on the com- puter-network lines. Simply connect the line to be protected to the UPS using the data-line protection con- nectors (IN and OUT) as indicated opposite (RJ45 cables not supplied). Page 14 - 34007231 oo/ad 2. Installation 2.7 Installation of the communications-card option 34007231 oo/ad - Page 15 3. Operation 3.1 Start-up A Press the ON / OFF button ©. The buzzer beeps and all the LEDs come ON. The buzzer beeps twice during the self-test, then button (15) remains ON, indicating that the receptacles are supplied with power.
- AC power is present: Only button @ is ON. The protected equip- ment is supplied by the AC-power source. - AC power is absent: Button (jj>) and LED @ are ON. The protected equipment is supplied by the UPS, operating on battery power.
All the connected equipment is supplied with power. NOTE: If button(T^ or LED(T) are not ON or if LED(T) is ON, there is a fault (see section 4.1).
Note: The battery is charged as soon as the UPS is connected to the AC-power source, even if button @ is in the OFF position. 3.2 Shift to booster or fader mode (during voltage variations in the AC-input power) A -© The booster and fader functions maintain the output voltage supplied by the UPS within close tolerances around the rated value even if signifi- cant voltage variations occur in the AC-input power. This avoids calling on battery power. The values defining the voltage range may be set using the UPS Driver software.
During operation in booster or fader mode, LED (21) is ON, signalling a significant voltage variation in the AC-input power. Page 16 - 34007231 oo/ad 3. Operation 3.3 Operation on battery power (following failure of AC-input power) Transfer to battery power The AC-input power is out of tolerances, LED (f(5) goes ON. During operation on battery power, the buzzer beeps every ten seconds. The equipment connected to the UPS is supplied by the battery. 4 {16 Threshold for the low-battery warning When the threshold is reached, the buzzer beeps every three seconds.
The low-battery warning threshold can be set by the user, with the 'UPS Driver' software. There is very little remaining battery backup time. Libro Para Aprender Piano Pdf Sheet. Close all appli- cations because UPS automatic shutdown is imminent. When the battery reaches the end of its backup time, the UPS shuts down and all the LEDs go OFF.
The equipment is no longer supplied with power. The UPS automatically restarts when power returns. NOTE: If the UPS does not restart, check that the 'automatic restart when power returns' function has not been disabled (see section 3.4 Personalization). 34007231 oo/ad - Page 17 3. Operation 3.4 Personalization (optional) Function Personalization parameters can be set and modified using the UPS Driver software installed on a computer that is con- nected to the UPS (see section 2.5 Connection to the RS232 or USB communications port). Check that the RS232 ( 6) communications cable is connected. UPS Driver installation: 1 - Insert the Solution-Pac CD-ROM containing the UPS Driver software in the drive of a PC running Windows.
2 - Open the Windows File manager or Explorer and select the CD-ROM drive. 3 - Double-click ' Emb Evolutio Config Setup.exe'.